Only when the working speed of the centrifuge is not at the critical speed, the rotor can move smoothly. For low-speed centrifuges with low operating speeds, the critical speed is generally increased as much as possible to allow the centrifuge to operate below the critical speed. The centrifuge has a very thick shaft and a high stiffness, called a rigid shaft. When the speed requirement is high, the critical speed is reduced as much as possible, the shaft is made thinner, the stiffness is small, called the flexible shaft, and the modern ultracentrifuge uses the flexible shaft.
The critical speed is related to the centrifuge and the associated rotor. A centrifuge can be equipped with several kinds of rotors. Therefore, the design of the centrifuge should consider the containment of the various vibrations of the centrifuge. Centrifuges have a wide operating range, from a few thousand rpm to tens of thousands of revolutions per minute. The higher the rotational speed of the centrifuge, the greater the risk.
Once the vibration occurs at high speed, the centrifuge should be stopped immediately by the speed reduction gear of Zui. All personnel should leave the scene quickly to avoid personal injury in the event of a broken shaft. Never power off, once the power is off, the brakes (fast speed reduction) are gone, and the rotor stops very slowly. The accident is generally caused by improper operation of the centrifuge. For example, if the rotor is not placed on the main shaft, the cover of the rotor is not covered, and the basket of the rotor is not placed. The structure of this accident is accompanied by a huge sound, and the 300-400kg Shanghai centrifuge suddenly rotates 270 degrees. Open the cover section to see the rotor lying in the cavity, take out the rotor section and observe that the outer edge of the rotor is severely scratched, the inner wall of the centrifugal cavity will be damaged, and even the refrigerant leaks. Sometimes the rotor and the rotor cover are separated, the liquid in the test tube is sprinkled in the cavity, and the spindle is broken or severely bent. Due to the frequent occurrence of such accidents caused by improper operation of the user, modern centrifuges generally have an imbalance protection function. That is, once the vibration of the rotor is greater than a certain size when the centrifuge is started, the centrifuge automatically stops at a speed. The centrifuge with such performance sometimes misses the report and cannot ensure that no accidents occur.
Centrifuge rotor machining error and centrifuge installation error will cause the rotor centroid to deviate from the centrifuge shaft to varying degrees. Therefore, vibration will occur when the rotor rotates. These vibrations will be inherent to the centrifuge drive system at certain speeds. The frequency resonates, causing the entire system to vibrate strongly. The speed at which this phenomenon occurs is called the critical speed.
The rotor will cause vibration when rotating at high speed, but the flexible shaft has "automatic alignment". The principle of action is that the rotor produces a disc effect at high speeds, and the elastic reaction force when the flexible shaft is bent pulls the rotor that is deviated from the geometric centerline of the main shaft back to the geometric centerline of the main shaft, and the vibration disappears. Of course, there is a certain limit to the amount of imbalance in the rotor at this time, and beyond this limit, the vibration does not disappear.
M-BUS metering data converter is with M-BUS and USB interface, which is collected with M-BUS meters and meter reading primary station separately. The communication with M-BUS meters is based on tree collection. This data concentrator is single non-communication converter, supporting data transmission and sending reading orders through USB collection. The quantity to collect with the meters(meters data transceiver) is 60pcs and 360pcs.
Function of the M-BUS converter:
Working voltage:AC220V
Power:10W
Interface: up:USB
down:M-BUS
Quantity:≤60pcs,360pcs
VBUS:high level 39V,low level 23V
BUS load current:≤200mA
Path protection:over current,short cut protection,reset automatically when failure deleted; need man resetting when long-time over current
Status indicator: power; receiving and sending; over load warning
wiring:0.75mm2~2mm2;wire resistance≤50Ω
transmission :1000meters
working environment:temperature:-30℃~80℃
humidity:≤90
M-Bus Converter,Wireless M-Bus Converter,Wireless Meter Reader,M-Bus Connector,Data Concentrator,Metering Data Converter,Meters Data Transceiver
Berggruen Technology Co.,Ltd , https://www.meter-technology.com